2026-10-14 Air Hub supply range 9–36 V instead of the family 8–32 V
- status: active
- date: 2026-10-14
- sunset: 2027-03-31
- deviates from:
bizplan/governance/product-plan.md§1 system voltage (12/24 V nominal, 8–32 V operating) for Air Hub, Air Hub Pro and Air Hub Mini - relatedTask: 20261014-2350-air-hub-docs-follow-hardware
Context
章节标题:“Context”The Linux carrier board of Air Hub and Air Hub Pro moved its 5 V rail from a discrete LMR36520 buck to a Mornsun K7805-2000R3 switching module (8–36 V input, 5 V / 2 A). The owner set the Air Hub supply range to 9–36 V continuous for all three products.
Decision
章节标题:“Decision”P05-air-hub.md R1.8 states 12/24 V nominal, 9–36 V continuous (§2.4, GW-05, §5). The upper
bound covers 24 V systems with margin above the family 32 V; the lower bound is 1 V above the
family 8 V.
Consequences
章节标题:“Consequences”Easier: one 5 V module on the carrier with a wide input and fewer buck components. Harder: on a
12 V system a deeply discharged battery or a starter dip to 8–9 V is outside the guaranteed
range, so Air Hub may reset where Core and Key keep working; sales and installation material
must state 9 V. The input stage drawn for 32 V must change before 36 V continuous holds: the
5.0SMDJ33A stand-off (33 V) is below 36 V (spec AIR-O-04). At the sunset date, either
amend the family rule for Air Hub or bring the lower bound back to 8 V.